Description
Product solution | MDL – MDS |
APPLICATION | Standard |
TECHNOLOGY | VLA VRLA |
MAINTENANCE | VLA = weekly VRLA = yearly |
DESIGN | IEC 60254-2 series L-E (2V DIN-BS cells) |
CAPACITY (C5) | 100-1550 Ah |
INTER-CELL CONNECTIONS | Bolted (std) |
DESIGN LIFE (CYCLES*) | VLA 1500+ VRLA 1200+ |
SINGLE POINT WATERING | Optional (VLA) |
AIR MIXING | Optional (VLA) |
ELECTROLYTE LEVEL SENSOR | Optional (VLA) |
CHARGING SOLUTION | 7 to12 hrs charging time with transformer or HF switching chargers |
ENERGY PACK CHARGER | MIDATRON MTB (VLA) MIDATRON MTT (VLA) MIDATRON HF |
BMU MODULE | Optional |
BATTERY CHANGE SOLUTION | YES |
Product solution | MLM |
APPLICATION | Low Maintanance |
TECHNOLOGY | VLA |
MAINTENANCE | quarterly |
DESIGN | IEC 60254-2 series L-E (2V DIN-BS cells) |
CAPACITY (C5) | 100-1550 Ah |
INTER-CELL CONNECTIONS | Bolted (std) |
DESIGN LIFE (CYCLES*) | up to 1500 |
SINGLE POINT WATERING | YES |
AIR MIXING | NA |
ELECTROLYTE LEVEL SENSOR | YES |
CHARGING SOLUTION | 7 to 12 hrs charging time ONLY with designed High Efficiency (HE) chargers |
ENERGY PACK CHARGER | MIDATRON HE |
BMU MODULE | YES |
BATTERY CHANGE SOLUTION | YES |
Product solution | MHE |
APPLICATION | High Efficiency |
TECHNOLOGY | VLA |
MAINTENANCE | weekly |
DESIGN | IEC 60254-2 series L (2V DIN cells) |
CAPACITY (C5) | 250-1000 Ah |
INTER-CELL CONNECTIONS | Welded |
DESIGN LIFE (CYCLES*) | up to 1800 |
SINGLE POINT WATERING | YES |
AIR MIXING | NA |
ELECTROLYTE LEVEL SENSOR | YES |
CHARGING SOLUTION | 7 to 12 hrs charging time ONLY with designed High Efficiency (HE) chargers |
ENERGY PACK CHARGER | MIDATRON HE |
BMU MODULE | YES |
BATTERY CHANGE SOLUTION | YES |
Product solution | MHEfast |
APPLICATION | High Efficiency FAST CHARGING |
TECHNOLOGY | VLA |
MAINTENANCE | weekly |
DESIGN | IEC 60254-2 series L (2V DIN cells) |
CAPACITY (C5) | 250-775 Ah |
INTER-CELL CONNECTIONS | Welded |
DESIGN LIFE (CYCLES*) | up to 1800 |
SINGLE POINT WATERING | YES |
AIR MIXING | NA |
ELECTROLYTE LEVEL SENSOR | YES |
CHARGING SOLUTION | fast charging ONLY with designed High Efficiency (HE) chargers |
ENERGY PACK CHARGER | MIDATRON HE |
BMU MODULE | YES |
BATTERY CHANGE SOLUTION | YES |